G3M Solid State Relays 5A Load Switching provided for the whole G3M product line • Thin design for high-density PCB applications. • DC input-AC output for a 3-A load or a 5-A load. • The 5A type is UL, CSA, EN (EN60950) approved. • UL and CSA compliance for 3-A Relays (-UTU models have TÜV compliance as well). • UL and CSA compliance for 5-A Relays (-VD models have VDE compliance as well). RoHS Compliant Refer to "Solid State Relays Common Precautions". ■Model Number Legend G 3 M -@ @ @@ @ -@ -@ ———— — — 1 2 3 4 5 6 1. Rated Load Power Supply Voltage 2: Maximum operating voltage lower than 264 V 4. Zero Cross Function Blank: Equipped with zero cross function L : Not equipped with zero cross function 2. Rated Load Current 03: 3 A 05: 5 A 5. Certification Blank: UL and CSA for 3-A models No certification for 5-A models UTU : UL, CSA and TÜV for 3-A models VD : UL, CSA and TÜV for 5-A models UTU-1 : UL, CSA and TÜV for 3-A models with reinforced insulation VD-1 : UL, CSA and TÜV for 5-A models with reinforced insulation 3. Terminal Type P: PCB terminals 6. Input Terminal Pitch Blank: 7.62 mm 4 : 5.08 mm G 3 M ■List of Models Isolation Input terminal pitch Zero cross function Indicator Rated output load Rated input voltage 5 VDC G3M-203P 5 VDC 3 A at 100 to 240 VAC 12 VDC G3M-203P 12 VDC 24 VDC G3M-203P 24 VDC 5 VDC G3M-205P 5 VDC 12 VDC G3M-205P 12 VDC 24 VDC G3M-205P 24 VDC 5 VDC G3M-203PL 5 VDC 12 VDC G3M-203PL 12 VDC 24 VDC G3M-203PL 24 VDC 5 VDC G3M-205PL 5 VDC 12 VDC G3M-205PL 12 VDC 24 VDC G3M-205PL 24 VDC 5 VDC G3M-203P-4 5 VDC 12 VDC G3M-203P-4 12 VDC 24 VDC G3M-203P-4 24 VDC 5 VDC G3M-205P-4 5 VDC 12 VDC G3M-205P-4 12 VDC 24 VDC G3M-205P-4 24 VDC 5 VDC G3M-203PL-4 5 VDC 12 VDC G3M-203PL-4 12 VDC 24 VDC G3M-203PL-4 24 VDC 5 VDC G3M-205PL-4 5 VDC 12 VDC G3M-205PL-4 12 VDC 24 VDC G3M-205PL-4 24 VDC Yes 5 A at 100 to 240 VAC 7.62 mm 3 A at 100 to 240 VAC No 5 A at 100 to 240 VAC Phototriac No 3 A at 100 to 240 VAC Yes 5 A at 100 to 240 VAC 5.08 mm 3 A at 100 to 240 VAC No 5 A at 100 to 240 VAC Minimum packing unit Model 100 pcs 1 G3M Solid State Relays ■Ratings Input (Each model has 5-VDC, 12-VDC, and 24-VDC input versions.) Rated voltage Operating voltage 5 VDC 4 to 6 VDC Impedance Must operate voltage level 300 Ω ±20% 4 VDC max. 12 VDC 9.6 to 14.4 VDC 800 Ω ±20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 1.6 kΩ ±20% 19.2 VDC max. Output Must release voltage level Item Model G3M-203P(L) 1 VDC min. G3M-205P(L) * Rated voltage 100 to 240 VAC Model Operate time Release time G3M-203P(L) 1/2 of load power source cycle + 1 ms max. 1.6 V (RMS) max. Leakage current Insulation resistance Dielectric strength Vibration resistance 1.5 mA max. (at 200 VAC) 1,000 MΩ min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min between input and output 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 1,000 m/s2 Shock resistance Ambient operating temperature −30°C to 80°C (with no icing or condensation) Ambient operating humidity Storage temperature G 3 M Weight 2 G3M-205P(L) G3M-@@@PL: 1 ms max. G3M-@@@P: 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 45% to 85%RH −30°C to 100°C (with no icing or condensation) Approx. 15 g Load voltage range Load current Inrush current 0.1 to 3 A * 45 A (60 Hz, 1 cycle) 0.1 to 5 A * 60 A (60Hz, 1 cycle) 75 to 264 VAC The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data. ■Characteristics Item Applicable load Approx. 25 g G3M Solid State Relays Load current (A) Load Current vs. Ambient Temperature 6 G3M-205P(L) 5 4 G3M-203P(L) One Cycle Surge Current: Non-repetitive Non-repetitive (Reduce the current under the dotted line of the impulse withstand current for repetitive operation) Inrush peak current (A) ■Engineering Data 70 60 50 G3M-205P(L) 40 G3M-203P(L) 3 30 2 20 1 10 0.5 0 -30 -20 0 20 25 40 60 80 100 Ambient temperature (°C) 10 30 50 100 200 500 1,000 5,000 Energized time (ms) ● Operating Environment Precautions The rated value for the ambient operating temperature of the SSR is determined under conditions when there is no heat build-up. (Left graph) Note that it is necessary to reduce the load current as the ambient temperature of the SSR may increase due to operating conditions. (Figure below is an example of the G3M-205P(L) model) When using the SSR, design the system to allow heat dissipation sufficient to stay below the Load Current vs. Ambient Temperature characteristic curve. Load current (A) Load current (A) Load current (A) Load Current vs. Ambient Temperature (Close Mounting) G3M-205 Series (5-A Load) 6 5 6 5 6 5 4 4 4 3 3 3 2.5A L=20.37ੈ 2 2.0A L=20.37ੈ G 3 M 2.5A L=20.37ੈ 2 1.8A L=12.7ੈ 2 1.8A L=12.7ੈ 1 0.8A L=7.62ੈ 1 0.8A L=7.62ੈ 1.5A L=12.7ੈ 1 0 −30 0.6A L=7.62ੈ −20 0 20 25 40 60 80 100 Ambient temperature (°C) 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) L L L L L L Top Top Top 3 pcs. 10 pcs. Bottom Bottom Bottom 10 pcs. 3 pcs. 10 pcs. • Thirty Relays are soldered to the PCB at each given spacing. • Continuous power. 3 G3M Solid State Relays ■Dimensions (Unit: mm) PCB Dimensions (BOTTOM VIEW) G3M-203P(L) G3M-203P(L) G3M-203P(L)-4 2.54 Four, 1.2 dia. holes Terminal Arrangement (BOTTOM VIEW) 2.54 Input voltage 9 max. 40 max. - Load power supply + Load G3M-203P(L)-4 20 max. 2.54 -4 Four, 1.2 dia. holes 3+ 2 1 LOAD INPUT 4 4±2 7.62 (5.08)* 12.7 10.16 0.7 0.4 2.54 1.5 *Input terminal pitch for models ending in "-4" is 5.08 mm. PCB Dimensions (BOTTOM VIEW) G3M-205P(L) G3M-205P(L) G3M-205P(L)-4 2.54 Four, 1.2 dia. holes Terminal Arrangement (BOTTOM VIEW) 2.54 Input voltage - 7.6±0.2 Load power supply + 40 max. Load G3M-205P(L)-4 G 3 M 2.54 25 max. 2.54 4 4±2 7.62 (5.08)* 12.7 10.16 0.7 0.4 1.65 *Input terminal pitch for models ending in "-4" is 5.08 mm. ■Precautions • Please refer to “Solid State Relays Common Precautions” for correct use. 4 -4 Four, 1.2 dia. holes 3+ INPUT 2 1 LOAD G3M Solid State Relays G 3 M • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K073-E1-07 1014(0207)(O) 5
G3M-203P DC12
物料型号:G3M系列固态继电器(SSR)

器件简介: - G3M系列固态继电器提供5A负载切换,适用于高密度PCB应用。

- 超薄设计,支持直流输入交流输出,负载电流有3A和5A两种规格。

- 5A型号具有UL、CSA、EN(EN60950)认证。

- 3A型号具有UL和CSA认证,-UTU型号还有TÜV认证。

- 5A型号具有UL、CSA认证,-VD型号还有VDE认证。

- 符合RoHS标准。


引脚分配: - 输入端子间距有7.62mm和5.08mm两种规格。

- 端子类型为PCB端子。


参数特性: - 每个型号都有5VDC、12VDC和24VDC输入版本。

- 输出负载电压范围100至240VAC,负载电流3A或5A。

- 操作时间和释放时间根据不同型号有所差异。


功能详解: - 部分型号具备零交叉功能。

- 绝缘电阻和耐压强度符合安全标准。

- 具有抗振和抗冲击能力。


应用信息: - 适用于需要高隔离电压和快速切换的应用。


封装信息: - 封装形式为PCB安装,具有不同的输入端子间距和零交叉功能选项。


注意事项: - 确保在没有热积累的条件下确定SSR的环境工作温度额定值。

- 设计系统时,确保足够的散热以保持在负载电流与环境温度特性曲线以下。

- 在实际应用中,确认设备功能和安全性后再使用产品。

- 在手册未描述的条件下使用产品或将其应用于可能对生命和财产有严重影响的系统或设备之前,请咨询OMRON代表。